In this article
The owner’s results identify limits of one no-gap workstation; counter deltas and later exclusions prevent turning a short successful run into a universal cooling claim.
A public owner report dated 29 July 2026 examines two directly adjacent RTX PRO 6000 Blackwell Workstation Edition cards. The hardware index summarizes useful power-split observations. Reading the detailed bundle and its later validation ledger adds an important qualification: a successful short exposure is not necessarily a validated steady operating point.
Preserve position, load and power split
GPU1 is the top card and GPU0 the bottom card, with no open-slot gap. Each runs an independent Qwen3.6-27B AWQ-INT4 vLLM engine with 32 concurrent requests. These are two active engines, not a single model split across the cards.
The 600 W bottom / 400 W top run lasts 30 minutes. The report describes the bottom settling near 81°C at 50% fan and the top near 88°C at 69–71% fan, with no recorded thermal-slowdown or hardware power-brake counter growth. The hotter top card consumes less power but needs more fan response. That is a local operating observation, not an isolated estimate of the effect of removing the slot gap: the available gap reference uses a different power split.
A sampled flag can miss a short limiting event
The original equal 500/500 W run lasts 10 minutes. Its software-thermal flag is never sampled active at 1 Hz, yet the top-card counter grows by 1.054 seconds, or 0.176% of the window. The distinction prevents a literal claim that no thermal limiting occurred.
The NVIDIA monitoring reference distinguishes software thermal slowdown, hardware thermal slowdown and software power capping. Their counters and sampled active states answer different temporal questions. A power cap deliberately reducing clocks is also not the same condition as temperature-driven limiting. Preserve the original field names rather than combining them into an unexplained “throttling” flag.
The later ledger changes the validation status
The validation status requires at least 3 admissible independent repetitions for internal validation. A retrospective fan-slope audit removes the original 500/500 W anchor: its automatic fan was still rising too quickly. The run registry preserves that exclusion.
Two later independently initialized 15-minute replacements pass the stated internal gates. The cell therefore closes at informative n=2, below the required threshold. Neither the asymmetric run nor these replacements establishes transferability: calibrated ambient and local-inlet probes were unavailable. Other later fan-policy cells have their own validation populations and should not be silently pooled into this automatic-fan result.
Keep an aborted exposure distinct from endurance
The equal 600/600 W attempt was intended to last 30 minutes but reached the owner’s 96°C safety cutoff after roughly five measured minutes. GPU1 accumulated 5.84 seconds of software and 0.28 seconds of hardware thermal slowdown. This supports a failed operating point for the tested no-gap configuration. It does not establish a completed endurance run or a universal manufacturer cutoff for every card.
The index separately describes a run where host CPU/CCD thermals were the principal concern, illustrating why a GPU-only view can miss the host limit. The sensor-location guide and chassis qualification guide explain the broader boundary. A spacing-effect claim would require matched power, workload, ambient conditions and fan policy with position or spacing controls. The published evidence is valuable precisely when its failed pilots, counter events and exclusions remain visible alongside its successful observations.
Earn rental income from GPUs