TECHNOLOGY

MuJoCo solref sweeps: timestep safety can change the effective time constant

In this article
THE QUICK TAKE

With refsafe enabled, a positive solref time constant is floored by the timestep rule; distinct authored values can therefore enter the same effective regime.

Different labels can enter the same numerical regime

A contact study progressively decreases the authored solref time constant but observes an apparent plateau. The report concludes that the material has become maximally rigid. Another possibility is that the requested values no longer differ after the engine’s timestep safety processing. Inspect the effective numerical regime before assigning a physical interpretation to the plateau. A table of XML values alone does not establish which constraint reference parameters were used internally.

Identify the positive parameter format first

The modeling guide gives positive solref entries the meaning of time constant and damping ratio. The direct negative format instead represents stiffness and damping parameters. Those formats are not interchangeable coefficient tables. State which one the study uses before discussing a time-constant floor. In particular, a rule conditioned on a positive first entry must not be generalized to every negative-format setting or used to interpret its magnitude as an elapsed time.

Trace the safety floor in the implementation

The inspected constraint-processing source checks that reference safety is enabled and the first solref entry is positive. It then uses the maximum of that entry and 2 × timestep. The resulting reference is used to derive constraint coefficients. Therefore requested positive constants below this boundary can be treated alike at a fixed timestep. Disabling refsafe removes that particular protection; it does not establish numerical stability or make an arbitrarily stiff setup physically accurate.

Propose a declared-regime comparison

A proposed model fixture should choose requested values on both sides of the safety boundary while holding timestep, impedance and other solver settings fixed. Record the expected processed reference and inspect a suitable constraint response. Then vary timestep as a separate experiment with its own configuration record. Do not combine timestep reduction and contact-parameter changes into a single material-only label. No numerical experiment or stability benchmark was performed for this article.

Record requested and processed assumptions

Acceptance evidence should retain effective contact-source selection, authored solref, its format, timestep, refsafe, impedance and engine revision. A geom-level value can also be changed by pair-resolution or override rules before this safety condition applies. Trace that chain rather than assuming the original field survives untouched. If direct internal coefficients are inspected, label them as derived quantities, not as replacements for the original experimental configuration or as a calibrated physical spring constant.

Keep numerical softness separate from material evidence

The GraspNet interpretation guide explains another model-parameter boundary; software reproducibility supports preserving numerical settings. Here the concrete result is an explained mapping from requested positive time constant to the solver’s protected regime. Agreement within that regime does not prove realistic penetration, restitution or contact forces. Those require a separate validation problem with measured physical observables and an explicit numerical convergence study.

Earn rental income from GPUs

Have idle GPUs or looking to fund AI infrastructure? Retrivium finds a rental platform, sets up the server and helps you assess income and costs with a pilot.

Explore GPU hosting
← All articles