In this article
A nested alias names the same FMI variable; the canonical variable reference remains globally unique and its declared type determines the accessor.
A second name is not a second signal
A twin dashboard imports a model description and creates an independent storage slot for every name it encounters. A canonical variable and its alias become apparently separate signals. Editing one display then appears to leave the other unchanged, although both refer to the same model value. Define canonical variable identity before building the user-facing name index. Otherwise the dashboard manufactures a disagreement that belongs to its own cache rather than the simulated plant.
Use the reference as a global variable handle
The inspected FMI specification requires valueReference to be unique across all variables of the FMU. The variable’s declared type determines the accessor to use. Do not allow different variable types to reuse a reference merely because the application has separate typed dictionaries. Validate the complete description before issuing calls, and retain both canonical name and type with the reference so a lookup cannot silently choose the wrong accessor.
Resolve nested aliases to the owning variable
The variable schema places Alias elements inside their owning variable. Alias names must be unique among variable and alias names. Floating-point aliases can carry display-unit information, which affects presentation rather than creating an independent physical state. Keep the alias-to-owner relationship explicit. If the application exposes editing through an alias, resolve the canonical variable and apply the intended unit conversion before using its appropriate setter under the model’s legal execution mode.
Test name resolution with deliberately conflicting metadata
A proposed parser fixture should include a valid variable with an alias, then invalid descriptions with duplicate references and duplicate names. The valid case should produce an additional lookup name without additional independent model storage. Invalid cases should be rejected with the conflicting definitions identified. Also inspect alias display metadata separately from raw values. No FMU parser was executed here; this is a proposed acceptance fixture for an importer implementation.
Record a canonical write trail
For an editable dashboard, retain the submitted name, resolved canonical reference, declared type, display convention and raw value sent to the model. Reading back through both names should resolve to the same canonical value with the appropriate presentation. Avoid comparing differently displayed numbers as if they were raw model disagreement. A cache should be keyed and invalidated around canonical identity, while alias labels remain views that explain how a user reached that value.
Distinguish model aliases from release aliases
The MLflow alias guide covers a different identity problem, while stack reproducibility supports preserving the imported model revision. Here acceptance establishes consistent names and accessors within a description. It does not guarantee compatibility after re-export, display correctness for every unit or physical validity of the signal. Preserve the model identity alongside references rather than assuming a handle is a universal identifier across unrelated FMUs.