In this article
Preserve the terminal status, stalled and reached_goal fields separately; the reviewed stall-success policy does not measure object retention or prove maximum physical force.
The action succeeded without reaching its position target
A grasp workflow waits for a gripper action to finish and treats SUCCEEDED as proof that the requested gap was reached. Under the reviewed legacy controller’s allow_stalling policy, that is not necessarily what success means. Preserve the result fields and configuration before interpreting the terminal status. This article concerns the reviewed Jazzy legacy position/effort GripperActionController path. Its behavior should not be assigned automatically to a replacement controller, a vendor driver or every action type with a similar name.
allow_stalling changes the policy for a detected stall
The Jazzy parameter page says allow_stalling permits action success when the gripper stalls while moving toward the goal. It also marks these legacy controllers as deprecated. Record the selected plugin and revision rather than presenting the example as a universal current controller configuration. A policy that permits stall success can be appropriate for some application-defined completion conditions, but it does not redefine a missed position target as a reached target.
The result fields remain distinct in the source
The reviewed implementation sets reached_goal true and stalled false in the goal-position branch. In the stall branch it sets reached_goal false and stalled true, then chooses SUCCEEDED or ABORTED according to allow_stalling. The action definition exposes those flags separately. An adapter should preserve them rather than replacing the whole result with a single completed boolean. Otherwise a later planner cannot distinguish position completion from a stall accepted by policy.
The reviewed detector is not an independent force measurement
The stall path follows low reported joint velocity lasting beyond its configured interval while position remains outside goal tolerance. It does not separately measure maximum physical gripping force in that condition. Its reported effort is assigned from computed_command, not a newly demonstrated force-sensor reading. Distinguish the action field’s intended description from the evidence supplied by this implementation. Lack of movement may reflect contact, obstruction, feedback behavior or another cause; do not convert the stall flag alone into proof that an object is securely held.
Exercise both outcome branches with synthetic feedback
Propose a nonactuating fixture with feedback that reaches the target and another trace that remains outside tolerance with low velocity. Compare allow_stalling enabled and disabled while preserving all other settings. Inspect terminal status and result fields together, including effort provenance. No gripper or controller was run here. Acceptance requires the documented policy distinction to survive the application adapter. It does not establish actual grasp success, object weight capacity, calibrated force or a safe next motion for a physical mechanism.
Define grasp completion outside the generic status
ACRONYM grasp geometry preserves another physical assumption. RoboNet gripper-target provenance distinguishes recorded and inferred action content. A legacy gripper record should retain plugin, thresholds, allow_stalling, result fields and any independent object-state evidence. Report position completion, accepted stall and verified grasp as separate claims. That makes the controller useful without asking a generic success status to prove a physical outcome it did not independently observe.
Earn rental income from GPUs
Have idle GPUs or looking to fund AI infrastructure? Retrivium finds a rental platform, sets up the server and helps you assess income and costs with a pilot.