In this article
Affinity regression, binder classification, and structure confidence require separate labels and evaluation targets.
A score column can hide a task substitution
A research ranking table may import every Boltz-2 output into a generic score field. That loses the difference between a predicted affinity value, a binder classification probability, and structural confidence. Sorting them as interchangeable numbers creates a different decision rule from the one each output was trained to support.
The Boltz repository identifies affinity prediction as part of the Boltz-2 generation. Keep the model generation explicit when interpreting exported results.
The affinity heads have distinct targets
The prediction guide distinguishes affinity_pred_value from affinity_probability_binary and explains that their supervision and intended contexts differ. The probability output is not a unit conversion of the regression output.
Retain the exact field names in the result schema. If an application creates a combined ranking, label it as an application-defined rule and evaluate that rule separately. A single display label such as confidence obscures the target being estimated.
Units and direction belong with the value
The documented regression value uses a logarithmic affinity convention tied to a stated concentration unit. Copying the raw number into a table labeled with a different unit or sign convention changes its meaning without changing its appearance.
Store the original value and a separately labeled conversion, if needed. Do not infer a physical free-energy measurement from a predicted assay-related output. The tensor-axis guide provides a related lesson: numeric compatibility does not establish semantic equivalence.
Supported inputs constrain interpretation
The guide specifies a small-molecule/protein affinity domain rather than unrestricted scoring of every biomolecular complex. The molecular schema parser also checks affinity binder selection and supported input relationships.
A process that returns successfully outside a well-supported scientific domain does not establish reliable estimates there. Preserve the target type, selected ligand, and relevant preparation decisions with the output rather than applying the same ranking interpretation to every structure prediction.
Evaluate each output against its own question
For a reproducible computational comparison, distinguish classification discrimination, regression behavior within the intended candidate domain, and structural assessment. Keep model revisions and input preparation fixed while changing the evaluated rule.
The benchmark methodology helps retain workload provenance, but runtime success cannot validate scientific accuracy. These outputs support model-based investigation; none should be described as experimental confirmation of binding or a verified therapeutic result.
Earn rental income from GPUs
Have idle GPUs or looking to fund AI infrastructure? Retrivium finds a rental platform, sets up the server and helps you assess income and costs with a pilot.