On the documented Orin configuration, changing the GPU partition mask after context creation can require reboot; label results with the completed transition, not only the request.
The benchmark starts after a warning was dismissed
An edge team selects a new Jetson power mode, dismisses a reboot prompt and immediately reruns its model. The report uses the requested mode name as though the hardware transition had completed. Before interpreting the result, preserve what the configuration operation actually reported. A queued or incomplete transition is a different experimental condition from the intended mode. The application may continue serving successfully while its environment still does not match the benchmark label.
The documented mask change has a lifecycle restriction
The Orin power-control guide says the GPU tpc_pg_mask can be set before creation of the golden context; a mode change requiring a different mask afterward requires reboot. This is a conditional platform rule, not a claim that every mode switch always reboots. Preserve the exact module and software release. A script that only records its requested mode identifier discards the transition evidence needed to decide whether the following run qualifies.
Separate the configuration check from the workload
For a proposed controlled comparison, record the existing mode and transition response, complete any required reboot through the authorized maintenance procedure, then inspect the supported current-mode query. Start a new measurement interval only after the application and model are ready again. A reboot also changes startup and cache conditions, so preserve them instead of comparing an unqualified cold run with a warm baseline. A mode identifier alone cannot establish equivalent inference preparation across the compared conditions.
Use telemetry to describe the running condition
The tegrastats reference defines observed CPU and GPU frequency, utilization and thermal fields. Keep the supported fields alongside the model interval and effective configuration. They describe what happened during that interval; they are not a replacement for the mode-transition check. Dynamic clocks and thermal control can affect a workload under the same profile. Likewise, a profile’s nominal watt label is not a direct measurement of constant board-input consumption.
Accept completed transitions without inventing a ranking
A dedicated test should exercise a supported transition and retain any warning, reboot boundary, current-mode result and representative telemetry. Include the interrupted transition as an explicitly unqualified case rather than assigning it the requested label. Acceptance means configuration provenance is explainable, not that a higher mode must be faster. No Jetson setting, clock or reboot was changed here, and no inference benchmark was run. The documented condition motivates a test; it does not supply measured performance for an appliance.
Preserve the difference from power-study conclusions
The corrected Jetson efficiency study concerns workload-specific rail measurements. AgriJetsonBench separately compares board-input observations and engine timing. This guide adds configuration evidence needed before making either kind of comparison. Report requested mode, completed transition, effective state and measurement boundary separately. That record can explain why a result is excluded without pretending that the documented reboot rule itself predicts speed, energy or the best deployment profile.