﻿# MuJoCo fixed tendons: joint bounds do not enforce a coupled travel limit

Model a coupled tendon-length constraint separately from individual joint ranges, including signed fixed-tendon coordinates and soft limit activation.

Author: Retrivium team
Updated: 2026-11-06
Canonical URL: https://retrivium.ai/journal/simulation-mujoco-fixed-tendon-coupled-length-limit/
Language: en

## Independent legal joints can form an illegal combination

A coupled finger mechanism passes every joint-range check, yet its modeled cable travel exceeds the intended limit. The application assumes legal joint coordinates imply a feasible assembly. That misses a relation involving several joints together. Define the coupled quantity explicitly rather than tightening each interval until one particular pose happens to pass. Independent interval bounds and a weighted-sum bound generally describe different configuration sets and can exclude different motions.

## Read fixed length as an abstract combination

The [MJCF tendon reference](https://mujoco.readthedocs.io/en/3.3.7/XMLreference.html) defines a fixed tendon using coefficients multiplying scalar joint positions and adding them into a length. This is different from a spatial tendon routed through geometric sites. Depending on the referenced coordinates and coefficients, the fixed quantity is an abstract signed combination, not necessarily a nonnegative measured cable distance. Preserve coefficient signs and units when mapping a mechanical coupling into that representation; a convenient name does not establish a physical routing model.

## Treat its range as a separate soft constraint

The [constraint reference](https://mujoco.readthedocs.io/en/3.3.7/computation/index.html) describes tendon limits as unilateral constraints, with activation related to distance from the relevant limit and its margin. They are not simply an input-array clamp that rewrites every submitted coordinate into a feasible pose. A configuration can therefore carry a limit violation whose correction is handled by solver dynamics. Inspect effective limit enablement and range independently from the limits of participating joints before interpreting a snapshot as accepted or rejected.

## Propose a coupled-configuration fixture

A proposed fixture should choose configurations whose individual joints remain inside their own intervals while the fixed-tendon combination crosses its range. Inspect the computed tendon length and relevant limit residual before evaluating subsequent motion. Include a configuration with the opposite coefficient contribution to reveal sign mistakes. Keep the same model and solver settings across cases. This isolates coupled-limit representation; no cable experiment or numerical response measurement was performed for the article.

## Retain the whole relation in acceptance evidence

Record tendon identity, joint names, coefficients, coordinate references, length range, margin and enabled state. A model export that keeps only individual joint limits discards part of the mechanism. If a feasibility gate requires strict satisfaction before simulation, implement and document that separate condition rather than assuming a soft dynamics constraint is a validator. When analyzing movement, distinguish a geometric violation, active corrective force and eventual task outcome instead of collapsing them into one binary status.

## Keep the coupling model narrower than hardware assurance

The [PartNet articulation guide](/journal/fg2-partnet-mobility-urdf-load-missing-mesh-cross-engine/) addresses another completeness condition; [software reproducibility](/journal/software-stack-reproducibility/) supports preserving coefficients and limits. Here acceptance establishes that the intended weighted relation is modeled and inspected separately from joint intervals. It does not verify cable elasticity, routing, slack or physical travel under load. Those require additional mechanism-specific evidence rather than inference from a mathematically convenient fixed-tendon definition.