﻿# W&B configuration changes: editing the experiment record does not reconfigure an existing optimizer

Keep Weights & Biases configuration records aligned with effective runtime settings, separating metadata edits, initialization inputs and time-varying training metrics.

Author: Retrivium editorial team
Updated: 2026-11-04
Canonical URL: https://retrivium.ai/journal/fg2-wandb-config-record-effective-runtime-state/
Language: en

## Trace the setting into the numerical object

A training script creates an optimizer, then updates its W&B config learning-rate field and assumes the optimizer changed. The [configuration guide](https://docs.coreweave.com/products/wandb/track/config) describes a dictionary-like experiment record. That record is not automatically a live control interface for every object the program already created. Identify where the model or optimizer reads each setting and verify the effective value used in computation before reporting the edited metadata as a new training condition.

## Preserve the resolved initialization state

The [initialization API](https://docs.coreweave.com/products/wandb/ref/python/functions/init) accepts configuration inputs and controls whether existing values may change. Resolve command-line arguments, configuration files and sweep values deliberately before constructing the numerical objects. Store the effective result after precedence rules, not several contradictory candidate sources. A useful record tells a later reader which values actually determined the run rather than merely listing a familiar default dictionary that was overridden elsewhere in the application.

## Separate changing measurements from fixed settings

A scheduled learning rate changes during training even if its initial configuration is fixed. Log the actual time-varying rate against the intended progress axis instead of repeatedly overwriting the only record of the initial setting. The [Run reference](https://docs.coreweave.com/products/wandb/ref/python/experiments/run) distinguishes configuration and logged history interfaces. Preserve both roles where needed: configuration explains how the schedule was defined, while history can explain which value applied at a particular training point.

## Treat metadata corrections as documented corrections

Correcting an inaccurate experiment label after completion can improve the record, but it does not rerun the computation or repair an artifact produced with a wrong parameter. Record the reason and supporting evidence for the correction. Avoid silently rewriting historical settings to match the desired experiment description. If the actual numerical setup is unknown, state that gap rather than converting an intended value into an unsupported claim about what the completed model training used.

## Test with an intentionally conflicting setting

Construct a controlled case with distinct requested and effective settings, then verify that the report preserves the value consumed by the optimizer and its subsequent schedule. The guides on [controlled experiment replay](/journal/data-guide-curriculum-order-controlled-replay/) and [logical feature schemas](/journal/data-guide-frictionless-table-schema/) provide related context. Accurate tracking requires a connection between metadata and runtime consumption. A configuration field is evidence when that connection has been established; editable metadata alone cannot change or prove the numerical history of a model artifact.