﻿# garak results: probes choose inputs, detectors score hits and evaluators decide passing

Interpret garak probe–detector results through the selected checks and threshold direction, preserving detector identity instead of reading PASS as a universal model property.

Author: Retrivium editorial team
Updated: 2026-11-04
Canonical URL: https://retrivium.ai/journal/fg2-garak-probe-detector-evaluator-score-direction/
Language: en

## Identify the three measurement stages

A scanner result combines input generation, observed responses and a rule for deciding whether those responses exhibit a targeted behavior. The inspected garak [probe implementation](https://github.com/NVIDIA/garak/blob/main/garak/probes/base.py) defines how attempts originate and which detectors are associated with a probe. Preserve those identities in the report. A broad category label can conceal substantial differences in both the inputs presented to the target and the behavior the detector actually recognizes.

## Read the detector's score meaning

The [detector contract](https://github.com/NVIDIA/garak/blob/main/garak/detectors/base.py) describes scores oriented toward detected hits, with larger values representing the targeted finding rather than generally better quality. Inspect the specific implementation before interpreting intermediate values as calibrated probabilities. Keyword checks and model-based classification have different failure modes. A string match can be useful evidence for a narrow requirement without being a complete semantic assessment of everything the response says.

## Keep threshold direction explicit

The inspected [threshold evaluator](https://github.com/NVIDIA/garak/blob/main/garak/evaluators/base.py) applies a rule that separates passing values from hits. Record the effective threshold and its direction alongside detector scores. Changing this decision rule can change pass rates without changing target responses. A dashboard displaying a larger percentage should therefore identify whether the value is pass rate, hit rate or another summary, rather than relying on a generic score label that reverses the reader's interpretation.

## Preserve multiple verdicts over shared outputs

Different detectors can examine the same generated responses. Their results are separate measurements, not necessarily independent additional model generations. Keep the association between attempt outputs and detector identity. If detectors disagree, inspect the narrow requirements each implements instead of averaging them into an unexplained capability value. Also retain missing or unscored outcomes according to the installed implementation, avoiding a silent conversion of unavailable measurement into an ordinary passing result.

## Validate the rule with benign fixtures

Use reviewed diagnostic outputs that contain the target pattern, discuss it harmlessly and omit it. Inspect how the chosen detector and evaluator classify those cases before interpreting a live scan. The guides to [mandatory acceptance rules](/journal/fg2-promptfoo-weighted-threshold-mandatory-assertions/) and [judge measurement contracts](/journal/fg2-deepeval-geval-steps-rubric-measurement-contract/) provide related controls. Report the probe, detector, threshold and target configuration together, preserving the difference between a repeatable finding under a defined rule and an unsupported general claim about every behavior of the evaluated model.