﻿# ContactPose MANO fits: a fitted hand mesh is not an independent surface measurement

Keep ContactPose annotated joints, MANO fitting settings and reconstructed meshes distinct when evaluating hand shape or contact-model inputs.

Author: Retrivium editorial team
Updated: 2026-11-04
Canonical URL: https://retrivium.ai/journal/fg2-contactpose-mano-fit-not-independent-hand-surface-measurement/
Language: en

## Identify the origin of the mesh target

A contact experiment loads a hand mesh and describes every vertex as directly measured from the participant’s hand. If the mesh was fitted to joint locations, that description hides the reconstruction model. Joint evidence can constrain articulation without uniquely measuring the soft-tissue surface between joints. State whether a target comes from annotated joints, a parametric fit or a direct surface measurement before using mesh agreement as evidence about anatomical shape or contact geometry.

## Read the fitting objective

The [ContactPose fitting source](https://raw.githubusercontent.com/facebookresearch/ContactPose/main/utilities/mano_fitting.py) fits a MANO model to hand-joint locations and includes shape regularization. The output therefore reflects both the joint data and fitting assumptions. Preserve the selected pose-space size, shape regularization and model version if recomputing the fit. A changed mesh can result from a changed fitting configuration even when the original joint annotations have not changed, so the two artifacts need separate provenance.

## Keep joint conventions explicit

The [author documentation](https://raw.githubusercontent.com/facebookresearch/ContactPose/main/docs/doc.md) defines the joint ordering and explains that joint locations are at finger-cylinder centers rather than on the hand surface. Do not compare those points directly with arbitrary surface vertices as though they represented the same anatomical landmarks. Record the mapping used when moving between joint conventions. A small mesh-to-joint discrepancy is not automatically an annotation error if the comparison confuses internal joint definitions with external surface geometry.

## Preserve the fit as a separate artifact

The [dataset loader](https://raw.githubusercontent.com/facebookresearch/ContactPose/main/utilities/dataset.py) exposes annotated joints and reconstructed MANO meshes through different paths and loads fit parameters separately. Keep that distinction in an export. If a model uses fitted geometry as input, report the fitted representation rather than calling it only hand pose. If evaluating against that representation, explain that the score measures agreement with a particular derived target, not an independent validation of all physical surface details.

## Inspect both the fit and its evidence

Compare the fitted model’s joints with the original annotated joints under a declared correspondence, then inspect the resulting surface separately. Preserve residuals rather than optimizing them away in a display-only alignment. [Image coordinate guidance](/journal/data-guide-image-exif-box-coordinate/) helps keep reference frames consistent; [software reproducibility](/journal/software-stack-reproducibility/) preserves fitting settings. This makes a ContactPose experiment interpretable as learning from measured annotations and model-derived geometry without confusing the reconstruction prior with additional independent evidence about the hand.
