﻿# Two Tesla P40s, one blower: the reported cooling limit

A dual-P40 home server reports hotter operation on small models. Examine what its shared printed duct demonstrates and which cooling measurements remain missing.

Author: Retrivium editorial team
Updated: 2026-11-05
Canonical URL: https://retrivium.ai/journal/dual-tesla-p40-shared-blower-cooling-case/
Language: en

A documented home inference server uses two Tesla P40 cards cooled by one 120×32 mm blower through a printed shroud. The [owner's account](https://dougfir00.com/local-llm-inference-server/), published March 1 and updated March 2, 2026, is useful because it reports a boundary rather than declaring the cooling universally sufficient: smaller models produced substantially hotter operation.

This is a single assembled system with owner measurements. It is not an independently reproduced cooling test or a recommendation that one fan can support any pair of passive accelerators.

## What the build actually reports

The server combines a Supermicro motherboard, dual Xeon E5-2680 processors and 96 GB of DDR3 memory. Its author reports roughly 57°C at an average GPU draw around 150 W, but over 77°C and over 220 W when running models in the seven-billion-parameter range. The owner concludes that one blower is probably insufficient for continuous use in that hotter workload.

The post also reports model-generation tests with a fixed prompt and five repetitions, but those are not a controlled comparison between cooling arrangements. It does not supply the blower's operating speed, measured inlet temperature, acoustic measurements or a synchronized per-card thermal series. The GPU power statements should therefore not be republished as calibrated whole-server power or a fully specified per-device stress protocol.

## Why the passive-board specification matters

NVIDIA's [P40 product brief](https://images.nvidia.com/content/tesla/pdf/Tesla-P40-Product-Brief.pdf) identifies a passively cooled board with 24 GB of GDDR5 and a 250 W maximum power limit. It explicitly requires system airflow to remain within thermal limits. Passive describes the board's cooling arrangement, not operation without moving air.

A shared shroud can direct flow toward both heatsinks, but a printed enclosure and fan dimensions alone do not establish the flow reaching each card. Installation geometry matters: the fan, duct, heatsink restrictions, card spacing and escape paths form one system. The general [host-qualification guide](/journal/gpu-server-chassis-cooling-qualification/) explains why software compatibility and thermal suitability need separate evidence.

The smaller-model observation is also a reminder that parameter count is not a cooling-load scale. A configuration that spends more time actively executing can produce a different power profile from a larger model bottlenecked elsewhere. That is a hypothesis to test here, rather than a mechanism established by this post.

## Measure each physical board over time

The [nvidia-smi reference](https://docs.nvidia.com/deploy/nvidia-smi/index.html) distinguishes temperature, power and clock-event observations, and notes that unsupported fields appear as unavailable. Its fan percentage describes intended speed on supported devices; many passive boards rely on enclosure fans instead. It cannot substitute for the external blower's tachometer or airflow measurement.

Retain stable device identifiers and aligned timestamps. Observe whether one card heats first, whether clocks change and whether application throughput falls after reaching a sustained thermal state. The [sensor-boundary explanation](/journal/gpu-inlet-device-temperature/) helps keep inlet air, GPU temperature and unavailable memory readings distinct.

## Compare a defined operating envelope

A useful follow-up would hold the model, prompt lengths, concurrency and power configuration fixed while comparing the shared duct with another qualified airflow arrangement. Include the hotter small-model case instead of validating only the coolest successful run.

Record ambient and inlet conditions, available blower speed, both boards' telemetry, completed work and whole-system consumption. If noise matters, record the acoustic method and measurement position rather than inferring quietness from the fan count. The resulting conclusion should name the workload and installation it sustained. The published build supplies a concrete starting observation and a reported limit, while leaving those controlled comparisons open.