﻿# Arc Pro B70 over USB4: warm decoding and cold-loading evidence

An author test reports a small warm decoding gap and slower loading over USB4. Preserve raw runs, the changed host and unisolated BAR explanations.

Author: Retrivium editorial team
Updated: 2026-11-05
Canonical URL: https://retrivium.ai/journal/arc-pro-b70-usb4-egpu-warm-cold-case/
Language: en

## The same card, two complete systems

Ntersection's [August 26, 2026 field report](https://ntersection.ai/blog/arc-b70-usb4-egpu) compares an Intel Arc Pro B70 with 32 GB of VRAM inside a USB4 enclosure against the same card installed internally. The external configuration uses a Ryzen mini PC, a 40 Gb/s cable and an enclosure reporting a PCIe 4.0 ×4 link. The internal configuration uses a desktop.

The author says the driver, runtime and model file match, but does not identify their exact versions or the model beyond a 30B-class hybrid mixture-of-experts model with approximately 24 GB of weights. Importantly, the host changes too. Thus this is a comparison of two complete configurations, not an experiment isolating only the cable.

## Preserve the warm and cold results separately

Three consecutive warm, single-request decoding runs report 46.3 / 45.5 / 44.7 tokens/s internally and 40.1 / 40.9 / 41.6 tokens/s externally. The model is already resident in GPU memory. The approximate 10% gap describes that condition; it does not establish throughput for concurrent serving, a partly offloaded model or a different context length.

Cold loading after dropping caches takes 11.1 seconds internally and 33.4 seconds externally. Prompt processing is described as within noise without numerical results. That wording cannot supply a measured prompt throughput or first-token latency. Keeping the actual observations visible is more useful than reconstructing a detailed benchmark from an incomplete protocol.

## The proposed mechanisms need stronger evidence

The report attributes the warm gap to extra host-device round-trip latency and the cold penalty to transfer bandwidth and a small CPU-visible memory window. Both are plausible explanations, but the published comparison lacks transfer traces, a matched-host test or a controlled BAR-size experiment. They remain interpretations rather than independently isolated causes.

The article's broad explanation of on-card bandwidth should also not become a universal rule for all autoregressive workloads. Whether bus traffic matters depends on tensor placement, offloading and execution behavior. A resident-weight, single-request result cannot determine a configuration that repeatedly moves layers or shares work across devices.

## A small mapping is different from small VRAM

On the external rig, the author reports a 256 MB CPU-visible window, absent firmware ReBAR options and a failed attempt to enlarge the window. That window is not the card's total device memory. [Intel's Arc Pro setup guide](https://www.intel.com/content/www/us/en/support/articles/000099073/graphics.html) emphasizes Resizable BAR for optimal performance, but does not certify this particular external enclosure or prove its measured slowdown mechanism.

[Linux PCI sysfs documentation](https://docs.kernel.org/PCI/sysfs-pci.html) distinguishes resource address information from the writable controls that can change device state. A retained read-only resource inventory can establish what was assigned during the tested boot. It cannot establish transfer speed by itself. The [Resizable BAR guide](/journal/gpu-resizable-bar-discovery/) explains that distinction without treating a large mapping as an automatic inference-speed guarantee.

## Discovery and service recovery still matter

The owner also reports that OpenCL discovery returns no platform while Vulkan serves the model. This is a useful backend-specific observation, not evidence that OpenCL fails on every B70 or that a missing platform means the physical GPU is absent. Preserve the API and driver path used for detection and the path that actually executes the workload.

A longer cold start can matter during recovery, model replacement or scaling even when ordinary warm requests avoid it. The [inference benchmark guide](/journal/inference-benchmark-method/) supplies the broader protocol. This case supports a bounded conclusion: the tested external configuration retained much of the reported warm decoding rate while loading substantially more slowly. The missing model identity, commands and matched-host control prevent a general USB4 performance promise.